May 11, 2016
2659 68th St
Description: Replace 5" curb trap, 4" fresh air inlet, and house drain and rain water conductor... pa one call #2016-1201721
- Permit #: 690601
Apr 22, 2016
2211 68th St
Description: To correct electrical violation - wire living space with switches, recepts ligths smokes onto an existing 100amp panel as per 2008 nec (west district)
- Contractor: Keys Jr. Joseph V. Keys Electric
- Permit #: 686505
Apr 1, 2016
925 68th St
Description: For building one (1) rear deck in an existing two (2) story structure
- Permit #: 681224
Mar 16, 2016
1819 68th St
Description: Install a 200amp service and install new wiring throughout with fishing wire thru walls only as per 2008 nec (west district)
- Contractor: Satterthwaite Terrell T M Satterthwaite E.C.
- Permit #: 676753
Jan 11, 2016
2215 68th St
Description: 2 wc,2 sink, 1 bathtub, 1 kitchen sink and 1 standpipe (sfd)the installation will comply with the philadelphia plumbing code 2004
- Contractor: Norman Cole Plumbing & Heating
- Permit #: 662838
Oct 29, 2015
2642 68th St
Description: Curb trap,lateral,fai pa20153011283(sfd)self certification's are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection"
- Permit #: 648770
Oct 23, 2015
2560 68th St
Description: Replace curb trap, fai & lateral pa20152931536 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection.
- Permit #: 647322
Oct 19, 2015
2558 68th St
Description: Replace 5" house trap, lateral 4" house drain & fai pa20152893023 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection.
- Contractor: Best Choice Plumbing, Inc
- Permit #: 646148
Aug 28, 2015
2014 68th St
Description: Install a mitsubishi-3-ton (36,000-btu)21 seer central a/c systejm.1-36k-btu condenser.3-interior(6k-btu) wall units.1 complete system.
- Permit #: 635421
Aug 27, 2015
2653 68th St
Description: Replace water service pa20152382013 (sfd)self certification's are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection"
- Permit #: 634901
Jul 2, 2015
2620 68th St
Description: Repair water dist pa20151610590 "self-certification's are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection"
- Permit #: 622126
Jun 12, 2015
3006 68th St
Description: Install garage door eliminate interior garage: for the elimination of an interior garage as part of an existing single family dwelling with (1) open air parking space as previously approved. close up garage door. frame opening, install door and siding on surrounding area. frame and install drywall on interior at basement level. (homeowner performed work)
- Permit #: 617358
Jun 12, 2015
3008 68th St
Description: Document the removal of (1) previously approved interior parking space
- Permit #: 616687
Jun 12, 2015
3012 68th St
Description: Install garage door eliminate interior garage: for the elimination of an interior garage as part of an existing single family dwelling with (1) open air parking space as previously approved. close up garage door. house built prior to '1962'. frame opening, install door and siding on surrounding area. frame and install drywall on interior at basement level. (homeowner performed work)
- Permit #: 617370
May 11, 2015
2504 68th St
Description: Replace water and drain lines in tub,toilet and sink (sfd)the installation will comply with the philadelphia plumbing code 2004
- Contractor: Best Choice Plumbing, Inc
- Permit #: 609060
Apr 24, 2015
2514 68th St
Description: Replace curb trap - new fai (sfd)pa 1 call - 2015-1120701 self certification's are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection"
- Permit #: 605385
Feb 3, 2015
2016 68th St
Description: Remove and replace fixtures with same pex 3 wc,3 lav,3 bath tubs & 3 kitchen (multi family)the installation will comply with the philadelphia plumbing code 2004
- Permit #: 588353
Dec 4, 2014
2024 68th St
Description: Install 2-em lights & 2-em exit light -( replace 3-horns, 3-pull stations & 2-smoke detector ***in kind with no add'l wiring) as per nec 2008
- Permit #: 577871
Sep 25, 2014
2548 68th St
Description: House trap & fai - pa1 call#2014-671994 - "self-certification's are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection"
- Contractor: Thomas Parisse Inc
- Permit #: 564017
Fire Incident History
02 Dec 2019
Building fires
Property Use:
Residential, other
Area of Origin:
Function area, other
First Ignition:
Liquids, piping, filters, other
Heat Source:
Hot ember or ash
31 Jul 2019
Mobile property (vehicle) fire, other
Property Use:
Outside or special property, other
Area of Origin:
Engine area, running gear, wheel area
Heat Source:
Heat from powered equipment, other
23 Jun 2019
Mobile property (vehicle) fire, other
Property Use:
Assembly, other
Area of Origin:
Other
First Ignition:
Item First Ignited, Other
Heat Source:
Spark, ember or flame from operating equipment
Incidents registered in Federal Emergency Management Agency
24 Oct 2015
Gas leak (natural gas or LPG)
Property Use:
1 or 2 family dwelling
26 Nov 2014
Heat from short circuit (wiring), defective/worn
Property Use:
1 or 2 family dwelling
18 Jul 2014
Arcing, shorted electrical equipment
Property Use:
Residential, other
Residents
Residence for Single Family
- 3 beds
- 1 bath
- Lot: 1,620 sqft
- Built in 1925
Facts
Lot size: 1,620 sqft
Rooms: 6
Stories: 2
Parking: Underground/Basement
Who has lived here
Residence for Single Family
- 3 beds
- 1 bath
- Lot: 1,624 sqft
- Built in 1925
Facts
Lot size: 1,624 sqft
Rooms: 6
Stories: 2
Parking: Underground/Basement
Who has lived here
Residence for Single Family
- 3 beds
- 1 bath
- Lot: 1,615 sqft
- Built in 1925
Facts
Lot size: 1,615 sqft
Rooms: 6
Stories: 2
Parking: Underground/Basement
Who has lived here
Residence for Single Family
- 3 beds
- 1 bath
- Lot: 4,140 sqft
- Built in 1925
Facts
Lot size: 4,140 sqft
Rooms: 6
Stories: 2
Parking: Underground/Basement